Fire-safe certified. Cryogenically tested. Safe in an emergency.The new safety class among shut-off valves
With the 2141 shut-off valve, GOETZE presents a solution for safety-critical applications in which both cryogenic temperatures and fire loads must be reliably controlled.
The stainless steel valve operates just as reliably at –328°F as it does after a 30-minute fire with temperatures of up to 1832°F.
Maximum safety – tested according to the latest standards
A unique selling point of the new 2141 cryogenic shut-off valve is its certification to ISO 10497:2024 and API 607, 8th Edition – the internationally recognized test standards for fire safety. These approvals ensure that the shut-off valve is fire-safe and will function reliably under fire conditions.
Tougher tested, more clearly defined, uncompromisingly safe.Why the new certification makes a difference.
The 2141 shut-off valve meets the highest fire safety requirements worldwide. GOETZE thus fully complies with not only current but also future safety standards:
- ISO 10497:2024 describes the test procedure in which the valve is exposed to temperatures of up to 1832°F for 30 minutes, including subsequent forced cooling, leak testing, and functional testing.
- API 607 (8th edition) specifies strict criteria for leak assessment during and after a fire.
- The fire safety test for the 2141 shut-off valve was carried out in a renowned test laboratory under the strict supervision of TÜV and confirmed with certificates.
The fire-safe test is not only a quality feature, but above all a safety feature for plant operators: even if a fire breaks out, the valve remains tight and can be operated later.
Want to know more about our products in the Technical Gases area?


High-quality materials, intelligent designStainless steel design for extreme applications
The 2141 shut-off valve is made of high-quality materials that can withstand both extreme cold and extreme heat. The sophisticated design ensures maximum tightness in cryogenic systems and in the event of a fire.
Safety when it mattersIdeal for highly sensitive applications


Whether methane, propane or other cryogenically liquefied gases: wherever cryogenic, combustible or fire-accelerating gases are handled, the 2141 shut-off valve offers maximum safety. The valve is ideal for cryogenic applications:
- In industrial applications
- In the energy sector
- Systems in potentially explosive areas – with combustible or fire-accelerating media
- Biogas plants, power-to-gas plants
- Gas filling stations
With the new 2141 series, GOETZE offers a cryogenic shut-off valve that sets new standards. Approved according to ISO 10497:2024 and API 607 (8th edition), GOETZE defines a new safety class in the field of stainless steel valves: A clear statement for technical safety, quality, and responsibility.
DO YOU HAVE ANY QUESTIONS? Looking forward to helping you!